 05017
CX12
thru
. . . engineered solutions for the transient environmentTM
CX12LC
COAXIAL PROTECTOR
APPLICA TIONS
High Speed Video Camera Coaxial Ethernet High Speed Data Lines
Surgebuster(R)
IEC COMPA TIBILITY (EN61000-4)
61000-4-5 (Surge): 24A, 8/20s - Level 2(Line-Gnd) & Level 3(Line-Line)
FEA TURES
Meets IEC 1000-4-5 Industry Requirements BNC Connection Low Capacitance Completely Enclosed Aluminum Housing Low Clamping Voltage Nanosecond Response Time Long Life and Maintenance Free Finger Safe Connectors
CX12 PACKAGE
MECHANICAL CHARACTERISTICS
Current - Amperes
FIGURE 1 TRANSIENT VOLTAGETHREAT CONDITION
2K
Metal Package Weight 161 Grams (Approximate) Device Marking: Part Number, Logo
1K
DESCRIPTION
The CX12 series is a two stage, hybrid surge protector designed to protect interfacing equipment from induced lightning or switching transients. The multistage technique has proven to be the most cost effective and reliable method for protecting sensitive electronic equipment. Employing state-of-the-art avalanche junction diode technology, these devices provide superior performance for video, Ethernet, Token Ring or other LAN interface systems. They are in-line modules with easy interconnecting terminals. A completely enclosed aluminum housing provides EMC shielding to meet industry standard requirements. The enclosure has two female BNC type connections for easy installation. The case is ground for those installations that require external ground connections. FIGURE 3 LINEAR VS NON-LINEAR CAPACITANCE
1000
IPP - Peak Pulse Current - % of IPP
Industry Standard Low Capacitance Solid State Protector
0
0
20
40
60 80 Time s
100 120 140
160
FIGURE 4 PULSE WAVE FORM
120
Current - Amperes
FIGURE 2 CX 12LC CLAMPING VOLTAGE
100 80 60 40
tf
Peak Value IPP
C - TVS Capacitance - pF
e-t
Test Waveform Parameters tf = 8s td = 20s
30 20 10 0 0 20 40 60 80 100 120 140 Time s 160
100 ProTek's CX12LC
td = t 20 0
IPP/2
10
0 1 2 3 4 5 V(OP) - Circuit Operating - Volts
0
5
10
15
20
25
30
t - Time - s Figure 1 and 2 are photographs of digitized waveforms showing a typical transient voltage and the clamping action of the CX12LC module. The device was subjected to a 2000A, 8/20s impulse waveform in accordance with ANSI C62.36. The CX12 has an operating frequency range up to 10MHz and the CX12LC up to 100MHz.
Figure 3 shows a comparison of capacitance between a industrial standard device (Top Line) and the ProTek Device CX12LC (Bottom Line). Due to the drastic change in the capacitance of the product (Top Line), signal distortion, loss of data or even access into the computer may be a problem.
05017.R2 7/02
1
www.protekdevices.com
CX12
and
CX12LC
DEVICE CHARACTERISTICS
MAXIMUM RATINGS @ 25C
Peak Operating Line Voltage (V OP ) Operating Line Current (I O ) Maximum Transient Voltage Maximum Transient Current Maximum Leakage Current CX12 Frequency Responce -3 dB CX12LC Frequency Responce -3 dB Operating & Storage Temperature Response Time 12 V 200mA 20kV 3000A (8/20s) 5A @ 30MHz @ 200MHz -40 to +85C < 10 ns
ELECTRICAL CHARACTERISTICS @ 25C
MAXIMUM CLAMPING VOLTAGE MAXIMUM LINE THRUPUT RESISTANCE R TYPICAL CAPACITANCE @ 0 V, 1 MHz C
PROTEK PART NUMBER
*
Line-Ground 500A @ 8/20 ms VC VOLTS
OHMS 3 10
pF 200 25
CX12 CX12LC
24 28
* Other Voltages Available Consult Factory
Frequency Responce CX12
1.21" (30.73 mm)
1.10" (27.94 mm) 1.40" (35.56 mm)
1.10" (27.54 mm)
Frequency Responce CX12LC
0.15" (3.81mm)
0.72" (18.29 mm)
EQUIPMENT
INST ALLA TION
The CX12 series is designed with a female BNC type connector on both ends for easy installation. Disconnect the video or data line from the sensitive equipment. Insert the CX12 in the line near the AC power outlet of the equipment to be protected. Install a cable in between the CX12 and the equipment to be protected. Attach a ground wire between the case of the CX12 and the equipment AC power ground, or to the coax shield as required.
0.72" (18.29 mm)
0.70"(17.78 mm)
05017.R2 7/02
2
www.protekdevices.com
LINE
CAUTION: Mounting plate must be CAUTION:Mounting plate must connected earth ground be connected toto earth ground CX12 COAXIAL LINE PROTECTOR CX 12 - COAXIAL LINE PROTECTOR
0.150" DIA. (3.81 mm) Mounting Holes
2.95" (74.93 mm)
3.25" (82.55 mm)
2.25" (57.15 mm)


▲Up To Search▲   

 
Price & Availability of CX12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X